Trimble Novapoint Help
In order for the 3D sign configuration function to accurately determine the reference height for the top foundation, it is essential to establish a consistent calculation basis within the Quadri for Windows. This calculation basis will serve as the reference point for measuring and positioning the top foundation element in relation to other components of the sign structure and the surrounding environment. This will help to prevent errors and inconsistencies that could arise from differing interpretations of how the top foundation height should be determined.
To establish a precise reference height for the top foundation of your road sign structure, it is essential to create an Elevation from Surface task within the Quadri for Windows environment.
The task are created in Quadri. Go to the NOVAPOINT ribbon and select Elevation from surface under Terrain.
Elevation from surface task can be created the following way:
Step 1: Go to Quadri.
Step 2: In the Explorer, select the correct summary task for the Elevation from surface task.
Step 3: Go to the NOVAPOINT ribbon and select Elevation from surface from Terrain.
Step 4: Enter a suitable name.
Step 5: Select subtask.
Step 6: Select the correct Calculation Basis for your design. The Calculation basis must cover the area of your design.
Step 7: Click Finish to create the task.
The Elevation from surface task can now be used by Novapoint Road Sign to calculate a reference height.