Novapoint 2022.6
FIXED: Chainage-order check was too restrictive making a message when the surfaces started with a BREAK.
Building model
IMPROVED: Handling of the areas where cross-sections overlap to produce better results.
FIXED: In some cases the roadmodel would build a cut into softspot where it was not specified.
Draw to CAD
NEW: Drawingstyle for Alignments to draw 3D station and symbol - Stylename: DRALIN_3DInfo
Chainage will be vertical text.
Tick-marker for chainage as sphere or vertical line.
3D polyline for alignment can be drawn from Alignment Design dialog.
Drawing Style Configuration
IMPROVED: Changes to the Swedish templates so they are readable in the configurator.
FIXED: Case of crash when entering Layer Manager on a specific element text.
Exports
NEW: LandXML exports in Quadri can merge multiple surfaces into one if they have neighbouring triangles.
Pick LandXML format
In settings - check the box for 'Combine Surfaces' and set an appropriate surface name
Pick conversionrule All 3Dsurfaces to LandXML via 'Combine Surface'-tool
Finish
It will combine multiple surfaces into one where it is possible.
The conversionfile that we have created does not push out the original surfaces to the file in addition to the combined surface. To get the original surfaces exported use f.ex. conversion rule Roadmodelsurfaces which has mapping to specific LandXmlObjectType.
The Export can also be combined with exporting alignment, just add the alignment and corresponding conversion rule.
This form of geometry in the exported file is important for some machining equipment.
FIXED: Quantity report would fail when chainage were very high (f.ex. ch. 500000).
NOVAPOINT WATER AND SEWER
WS Design tool - Quadri model
IMPROVED: Upgrade from old to newer Quadri model, the Upgrade tool now also include upgrade of WS task conversion rule(s).
NEW: Added new feature type for Stakeout Pipe Reference Line
WS Construction (CAD)
FIXED: Deleting a new trench from an existing node did not delete the connected manholes. Single manholes remained in Node.
IMPROVED: When adding a new trench user are now asked to allow connection by network type.
IMPROVED: When deleting a connection, a message is added that inform user if one or more properties are “locked”, and thus cannot be deleted.
NOVAPOINT RAILWAY
(Note: Also review changes for Novapoint Road as many also applies for Novapoint Railway)
Railway Alignments
Fixed: Case of hanging when working with/drawing out alignment that has only one element in it.
NOVAPOINT TUNNEL
FIXED: Export of rock support doesn't crash anymore FIXED: Cross-section drawing: The dynamic numbering works now.
NOVAPOINT ROAD SIGN
Finnish Version
New
The program has been updated with support for a number of the new signs launched by the Finnish Road Administration 01.06.2020 and updated in 2021 and 2022. The new version of the sign program can for a transitional period run in parallel with the version of the program that supports the previous standard.
Enhancements
Route No. - Added support for route numbers with dashed border (#HAN-5224)
C43x - Geometry updated based on the updated design standard from 2022 (#HAN-5306)
E6 - Geometry updated based on the updated design standard from 2022 (#HAN-5307)
E15_3 - Geometry updated based on the updated design standard from 2022 (#HAN-5308)
E16_3 - Geometry updated based on the updated design standard from 2022 (#HAN-5309)
E19 - Geometry updated based on the updated design standard from 2022 (#HAN-5311)
E20 - Geometry updated based on the updated design standard from 2022 (#HAN-5312)
F10 - Added support for more arrow combinations (#HAN-5310)
F10 - Update horisontal alignment of content based on the updated design standard from 2022 (#HAN-5330)
F20.2 - Added support for “Add” plate (#HAN-5322)
F21.2 - Added support for more “arrows” based on the updated design standard from 2022 (#HAN-5323)
G1 - Updated vertical distance to “color field” based on the updated design standard from 2022 (#HAN-5324)
G41.1 - Added support for TH=100 based on the updated design standard from 2022 (#HAN-5325)
H4_2 - Added support for new sign (#HAN-5342)
H12.3x - Added support for missing combinations (#HAN-5331)
H12.6x - Added support for missing combinations (#HAN-5332)
Fixed
General - The width of border was not ok for a number of F-signs for TH=150 (#HAN-5343)
TSEXPLODE - It was not always correct color for “inner boundary” if display mode is RGB (#HAN-5220)
E4.1_5_1 - The sign was missing in the dialogue (#HAN-5310)
E4.1_5_2 - The sign was missing in the dialogue (#HAN-5313)
H17.3_2 - The geometry for white boundary on text not correct when blue background (#HAN-5321)
H20_2 - The geometry for white boundary on text not correct when blue background (#HAN-5317)
Norwegian Version
Enhancements
829.1a - Added suppoert (#HAN-5119)
Fixed
850.0 - Added support for more combinations in size (#HAN-5127)
834.x - The width of sign in LS can now be 600mm or 500mm (#HAN-5128)